<LOGO>
FM Transmitter Measurement Report
Created: 2024-07-27 12-01-26
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.70 MHz 3/5, 29 dBuV R-PCE
Pilot RDS Phase Difference
6.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
20 kHz 28 kHz 2635 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,7 dBr -0,56 dBr 0,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PCE " 280C 9 (Varied) 1 0 1 5 12:01, 27.07.2024
RT
"Zpravy z regionu - rozhovo - dobre rady - soutezc# "
AF EON
88.9, 93.6, 93.7, 98.6, 101.0, 102.2, 102.4, 103.3, 104.7 MHz -
FM Scope Max at: 28 kHz MIN: 20 kHz % above 77 kHz: 0,0000 Acquired: 2024/07/27 12:01:23 Total samples: 2635 Equivalent time: 0:02:11 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150
FM Scope MAX: 0,1 dBr MIN: -1,7 dBr AVE: -0,56 dBr % above 0,2 dBr: 0,0 Last value: -0,6 dBr (2024/07/27 12:01:22) 11:48 11:50 11:52 11:54 11:56 11:58 12:00 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality